Description
MV1100 Load resistor contains three ganged resistors with continuous spindle regulation. The resistors are connected to terminals for 3-ph, single-phase or DC-voltage. The current in the resistor is limited by tubular wire fuses in each phase. The unit has handles and wheels for simple and quick movement and is enclosed in a perforated metal cabinet. A cooling fan is placed at the bottom of the resistor.
MV 1100-235 Cooling fan supply 230 V AC 50 – 60 Hz
MV 1100-116 Cooling fan supply 110 V AC 60 Hz
General Data |
3-phase 3.3 kW, continuously adjustable. |
Star connection |
400 / 230 V 0.8-5 A |
Star connection |
230 / 133 V 0.5-5 A |
Delta connection |
400 / 230 V 2.4-8.7 A |
Delta connection |
230 / 133 V 1.3-8.7 A |
DC parallel connection |
220 V 2.3-15 A |
Overload capacity, brief duration, approx. 20 %. |
|
Dimensions |
630 x 250 x 890 mm |
Weight |
46 kg |