Description
General
PST2210 Power Plant Module with 2.2 kW 3-phase AC Induction Motor and Field Oriented Programmable Drive for simulating a turbine with different characteristics as:
- Steam turbine (nuclear, geothermal, fossil)
- Hydro-electric turbine
- Small diesel motor
The three-phase 1.2 kVA synchronous generator has electrical parameters similar to real units. Manual or automatic control both for the frequency (=active power) and the voltage (=reactive power). One-line mimic diagrams together with power breakers and isolators and groups of digital instruments arranged in the same way as in real plants.
The PST2210-module has also synchronization and phasing devices, digital bar-graphs for voltage and frequency, step-up transformer, current and voltage transformers, relay protections, A and B bus bars with two outgoing lines.
Operation of breakers and isolators is controlled and interlocked by PLC’s for safe operation by students. The step-up transformers can be operated individually and all terminals are available from the front panel providing access to delta and star-connected windings.
Access to the generator windings are provided on the front panel.
Protection relay current transformer windings are accessable on the front panel via external connectors. Possibility for floating, impedance and direct-earthing of transformer and generator is available on front panel.
PST2210 contains a fault simulator with the ability to simulate variable short circuit and earth faults.
The module includes 4, 8-pole Transfer Blocks for easy signal transfer between different compatible modules.
Possible earthing methods:
- a) Solid earth
- b) Resistive earth
- b) Floating earth
Technical Specifications
Simulating different types of power plant units:
- Induction Motor 2.2 kW @ 50 Hz, 2.6 kW @ 60 Hz
- Fully programmable AC Drive with HMI for Speed/W control
Step-up Transformer
- Step-up Transformer 230 / 400 V, 2.0 kVA
Generator Data:
- 4-pole Synchronous Generator, 1.2 kVA, cos phi 0.8
- Static PWM rectifier for Voltage / VAr control
- Voltage: 3 x 230 V
- Nominal Current: 3.5 A
- Frequency: 50 Hz / 60 Hz
- Speed: 1500 rpm / 1800 rpm
- Synchronous Reactance 97 %
- Transient Reactance 17 %
- Sub Transient Reactance 8 %
Digital Instruments:
Multiple 3-ph Power Energy Meters displaying 20 values for U, I, P, Q, S, and cos phi is used for:
- Generator
- Step-up Transformer
- Outgoing Lines 1+2
- External Grid
Selectable-line Double-busbar Voltmeters:
- Field Current
- Rpm
- Frequency (Set point, actual)
- Synchroscope for Phase Position, ∆ frequency and ∆ voltage
- Bargraphs for Voltage and Frequency
Number and type and configuration of the ABB Intelligent Electronic Devices (IED) are different depending on the complexity or Level that is desired.
Included in all levels:
- IEC61850 GOOSE device information sharing capability
- Easy Parameter Setting Via Web Browser
- Disturbance Recording for in-depth fault analysis
Measurements |
|
|
Cubicle |
WxHxD |
1560x1900x1075 mm |
Weight |
|
360 kg |
Turbine/Generator |
|
|
Cubicle |
WxHxD |
300x560x1500 mm |
Weight |
|
90 kg |
Power supply
400V 3-phase, 16A. Each module connects 5 pole (L1, L2, L3, N, Earth) with CEE connection.
Protection Relays
PST2210 Level 1
IED Transformer + Generator Protection (1 unit – RET630):
- Differential Protection
- Over/Under Voltage Protection
- Frequency Protection (Over/Under/Gradient)
- Negative Sequence Overcurrent Protection
- Neutral Point Earth Fault Protection (Residual Over-Current)
- Neutral Point Earth Fault Protection (Residual Over-Voltage)
- HV / MV Overcurrent Protection
*1 Protection unit in total
PST2210 IED Level 2
IED Transformer + Generator Protection (1 unit – RET630):
- Differential Protection
- Over/Under Voltage Protection
- Frequency Protection (Over/Under/Gradient)
- Negative Sequence Overcurrent Protection
- Neutral Point Earth Fault Protection (Residual Over-Current)
- Neutral Point Earth Fault Protection (Residual Over-Voltage)
- HV / MV Overcurrent Protection
IED Outgoing HV Line 1 & 2 Multi-Protection (2 units – REF615):
Directional Three-Phase Overcurrent
- Protection
- Directional Earth Fault Protection
- Three-Phase Overcurrent Protection
- Non-Directional Earth Fault Protection
- Negative Sequence Overcurrent Protection
- Phase Discontinuity Protection
- Negative Sequence Overcurrent Protection
- Auto Reclosing Function
*3 Protection units in total
PST2210 Level 3
IED Transformer + Generator Protection (1 unit – RET630):
- Differential Protection
- Over/Under Voltage Protection
- Frequency Protection (Over/Under/Gradient)
- Negative Sequence Overcurrent Protection
- Neutral Point Earth Fault Protection (Residual Over-Current)
- Neutral Point Earth Fault Protection (Residual Over-Voltage)
- HV / MV Overcurrent Protection
IED Dedicated Generator Protection (1 unit – RET615):
- Differential Protection
- 95% Stator Earth Fault Protection
IED Incoming HV Line 1 & 2 Multi-Protection (2 units – REF630):
- Distance Protection
- Directional Earth Fault Protection
- Directional Three-Phase Overcurrent Protection
- Non-Directional Three-Phase Overcurrent Protection
- Non-Directional Earth Fault Protection
- Phase Discontinuity Protection
- Negative Sequence Overcurrent Protection
- Reverse Power Protection
- Auto Reclosing Function
*4 Protection units in total